1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments GX-2009 Personal Gas Monitor, 3 Gas, LEL / H2S / CO with Alligator Clip and 12 VDC Charger and Vehicle Plug - 72-0312RKA

Item #:
72-0312RKA
Brand:
RKI Instruments
RKI Instruments GX-2009 Personal Gas Monitor, 3 Gas, LEL / H2S / CO with Alligator Clip and 12 VDC Charger and Vehicle Plug - 72-0312RKA
$614.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments GX-2009 Personal Gas Monitor, 3 Gas, LEL / H2S / CO with Alligator Clip and 12 VDC Charger and Vehicle Plug - 72-0312RKA

RKI Instruments GX-2009 Personal Gas Monitor, 3 Gas, LEL / H2S / CO with Alligator Clip and 12 VDC Charger and...

$614.00

72-0312RKA GX-2009 Personal Gas Monitor, 3 Gas, LEL / H2S / CO with Alligator Clip and 12 VDC Charger and Vehicle Plug by RKI Instruments

Workplace safety is a top priority at RKI Industries. With a reputation as being a world leader in gas detection and sensor technology, the company invests heavily in their research and design team to develop the industry's leading workplace safety products. The GX-2009 Model Personal Four Gas Monitor utilizes advanced technology and efficient design. It is the world's smallest and lightest gas monitor.

The GX-2009 Model Personal Four Gas Monitor

The GX-2009 Model Personal Four Gas Monitor is an obvious choice for many particularly hazardous applications. From personal monitoring in confined spaces to its use in fire services and construction, the portable monitor has been rated intrinsically safe. Its noticeable alarm functions and simultaneous detection of four separate gases help to ensure the safety of workers in potentially dangerous situations. The state of the art monitor can detect LEL, O2, H2S, and CO simultaneously and display the results on the large LCD display screen.

Each of the miniature sensors are manufactured with the high quality control standards of RKI Instruments. The compact sensors utilize catalytic combustion, electrochemical, and galvanic sensor technology.

Alarm System

The unit features dual audible alarm ports at 95 dB, and three bright LED lights for noticeable alerts. The Personal Four Gas Monitor also utilizes an ultra strong vibration alert designed to notify users of atmospheric conditions even when the device cannot be heard. When the monitor is in alarm mode, the backlight on the LCD display is turned on. The multi-faceted alarm system is designed to be noticeable in any given situation and is sure to notify the user and those nearby.

Standard Features

The GX-2009 Model Personal Four Gas Monitor has many standard features including an incredible datalogging function. The datalogging software can store up to 100 calibration records and is compatible with many computer platforms. The log time can range from 10 to 300 hours and houses 8 alarm trends. The unit can also remind users of upcoming calibration and bump tests. With 2 glow in the dark, glove friendly buttons, users can easily operate the device on site.

The unit comes standard with an alligator clip, NiMH batteries, a charging station with VAC power supply, and a product CD with datalogging software.

Specifications

The GX-2009 Model Personal Four Gas Monitor is the smallest and lightest personal gas monitor in the world. Weighing in at less than 5 ounces, the device fits easily in the palm of a hand and is easily portable. Additionally, the IP-67 water resistant and dustproof design contains an impact resistant over mold rubber body to protect the integrity of the device. The unit uses a set of 2 NiMH batteries with 20 hours of operation. Each GX-2009 Model Personal Four Gas Monitor comes standard with a 2 year warranty for materials and workmanship.

*Please note we can only ship RKI products to customers within the United States

Gas Detected
Combustible Gases
(Methane as standard)
Oxygen (O2)
Hydrogen Sulfide (H2S)
Carbon Monoxide (CO)
Detection Principle
Catalytic combustion
Galvanic cell
Electrochemical cel
Detection Range (Increments)
0 ~ 100% LEL (1% LEL)
0 ~ 40.0% Vol.
(0.1% Vol.)
0 ~ 100.0 ppm (0.5 ppm)
0 ~ 500 ppm (1 ppm)
Accuracy Statement
± 5% of reading or ±
2% LEL ( which ever is greater)
± 0.5% O2
± 5% of reading or ±2 ppm H2S (which ever is greater)
± 5% of reading or ±5 ppm CO (which ever is greater)
Sampling Method
Diffusion sampling standard / hand aspirator or motorized pump optional
Display
Digital LCD displays all four gases simultaneously, with auto backlight
Preset Alarms (User Adjustable)
(Over alarm Non-adjustable)
1st alarm: 10% LEL
2nd alarm: 50% LEL
Over alarm: 100% LEL
Low alarm: 19.5%
High alarm: 23.5%
Over alarm: 40.0%
1st alarm: 10 ppm
2nd alarm: 30 ppm
TWA alarm: 10 ppm
STEL alarm: 15 ppm
Over alarm: 100 ppm
1st alarm: 25 ppm
2nd alarm: 50 ppm
TWA alarm: 125 ppm
STEL alarm: 200 ppm
Over alarm: 500 ppm
Types of Alarms
Gas Alarm: 2 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
Trouble alarm: Sensor disconnection, wire disconnection, low battery, circuit error, calibration range error
Display of Alarm
Gas Alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), flashing gas value, vibration
Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
Operating Temp. & Humidity
-4°F to 122°F (-20°C ~ +50°C), 0 to 95% RH on-condensing (splash resistant)
Response Time
Within 30 seconds (T90)
Continuous Operation
20 hours after a 3 hour full charge (14 hours after 90 min charge)
Power Source
Direct charging NiMH batteries, set of 2
Safety Design /Approvals
IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; CSA classified, “C/US”, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Dimension & Weight
2.7” H x 3” W x 1” D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130 g)
Case Material
High impact over molded rubber. Dust and water resistant with IP-67 approval
Controls
Two glow in the dark buttons: POWER / MODE, AIR
Datalogging
Standard with all instruments. Stores 8 alarm trend sessions where readings are recorded 30 minutes before and after an alarm event. 3,600 data point capacity with a log time range of 10 to 300 hours (based on programmable interval times); and stores up to 100 calibration records
Required Accessories
Battery charge
Standard Accessories
Alligator clip - 13-0116RK
NiMH batteries (set of 2) - 49-1609RK
Charging station with 115/220 VAC power supply (also available without power supply, 49-2170RK) - 49-2170RK-01
Product CD (includes datalogging software) - 71-8002RK
Optional Accessories
Belt Clip - 13-0117RK
Padded carrying case for GX-2009 and accessories - 21-0112RK-01
Charging station, 115/220 VAC powered for 2, 3, 4, or 5 instruments - 49-2170RK-XX
Charging station with 12 VDC power supply and vehicle adapter plug - 49-2171RK
12 VDC adapter with vehicle plug (does not include charger base) - 49-2020RK
RP-6 sample drawing pump with 10’ hose and probe - 81-1166RK
Hand aspirated sample draw with 10’ hose and probe - 81-1160RK
USB to IrDA downloading cable - 47-5027RK
SM-2009U single calibration station - 81-SM2009U
Configurations
4 gas, LEL / O2 / H2S / CO
2 gas, LEL / O2
Single gas LEL / O2 / CO / H2S
3 gas, LEL / O2 / H2S
2 gas, O2 / H2S
3 gas, LEL / O2 / CO
2 gas, O2 / CO
Warranty
Two years material and workmanship