- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach 6600-8053 MGS-550 Safety Compliance Gas Detector - IP66, 5-digit LED (consentration level), Analog and (3) Relay Outputs, Modbus, (1) Factory Installed IP66 Sensing Head - HFO1234ZE, 0-1,000 ppm, SC
Item #:
6600-8053
Brand:
Bacharach
Share this product:
6600-8053 MGS-550 Safety Compliance Gas Detector - IP66, 5-digit LED (consentration level), Analog and (3) Relay Outputs, Modbus, (1) Factory Installed IP66 Sensing Head - HFO1234ZE, 0-1,000 ppm, SC by Bacharach
Bacharach's MGS-550 leak detector combines electrochemical, semiconductor, catalytic bead and infrared sensors into one platform to support leak detection for the new low GWP (Global Warming Potential) refrigerant blends as well as natural refrigerants to enable gas leak detection in the often harsh environments of industrial refrigeration.
The MGS-550 can easily be integrated into any building management system (BMS). The Modbus RTU interface allows the user to program and configure the unit remotely through the BMS. Remote access gives complete control to the user when using Modbus. Alternatively, electrical current or volt analog output provides an industry standard reading using 4-20mA.
Having three integrated relays within each instrument reduces the need for having to wire alarm devices back to a central control system. Because of the integrated relays, the Bacharach MGS-550 can be operated as a stand-alone system. Each relay can be individually programmed to trigger alarm devices and actions separately or as a redundant system.
The straightforward menu structure is identical regardless of the type of sensors used, reducing the costs and amount of time for training required upon installation or during maintenance.
Bacharach's MGS-550 offers the flexibility of adding a second sensor at any point in time without the need for any additional controllers. Any sensor can be remotely mounted from the main instrument to a distance of 5 meters or 15 feet. It meets the requirements of EN 378 and ASHRAE 15.
Features
- One or two sensor capability
- Remote sensor capabilities
- Analog and digital interface
- On-board relays
- Magnetic wand
- Status indicator and LED display
- Optional MGS-408 Controller
Benefits
- Detects two gases and/or in two locations with one instrument
- Flexible placement in hard to reach areas
- Ease of integration with multiple control devices
- Connects to local alarm devices for saving costs on installation
- Non-intrusive configuration and calibration
- Provides at-a-glance status overview and comprehensive direct user interface
- Create an independent, centralised alarm system with up to 6 gas detectors
Gases and Range | Refrigerants | 1,000 / 10,000 ppm |
CO2 | 5,000 / 10,000 / 20,000 / 30,000 / 40,000 / 50,000 ppm | |
NH3 | 100 / 1,000 / 5,000 / 10,000 ppm / 100% LEL | |
O2 | 30Vol% | |
CO | 500 / 1,000 ppm | |
Combustible Gases | 5,000 ppm / 100% LEL | |
C2H4 | 2,000 ppm | |
NO2 | 20 ppm | |
Repeatability | ±5% of applied gas concentration | |
Display | Red 5-digit, 7-segmented LED and green status LEDs | |
Output | Analog | 4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V |
Digital | Modbus RTU via RS 485 | |
Power Supply | 19.5 to 28.5 VDC or 24 VAC ±20%; 3- or 4-wire | |
Relay | Three relays, SPDT, user assignable | |
Rating 2 A @ 30 VDC NO, 0.5 A @ 125 VDC, 0.25 A @ 250 VAC, 30 W, resistive load | ||
Enclosure | General purpose | ABS IP66 with four M20 x 1.5 cable glands |
Size (WxHxD) Approx | General purpose | 8.3" x 8.9" x 3.4" / 210 x 225 x 85 mm |
Weight Approx | GP: 2 lbs / 1 kg; XP: 3.5 lbs / 1.6 kg | |
Approvals | CE, UL / CSA / IEC EN 61010-1 | |
Ambient Conditions | Temperature | Semiconductor: -40 to 122°F / -40 to +50°C |
Electrochemical: -5 to 122°F / -20 to + 50°C | ||
Infrared: -40 to 122°F / -40 to +50°C | ||
Catalytic Bead: -40 to 122°F / -40 to +50°C | ||
Humidity | 5 to 90 % RH, non condensing | |
Pressure | 23.6 to 32.5 inch Hg / 800 to 1,100 mbar |