1-866-4 JJSTECH(1-866-455-7832)

Bacharach 6302-2070 MGS-450 Gas Detector - IP66, 3 x Relays, Analog Output, Modbus Output, Audible & Visual Alarms - NH3, 0-100% LEL, Catalytic Bead

Item #:
6302-2070
Brand:
Bacharach
$1,017.90
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 6302-2070 MGS-450 Gas Detector - IP66, 3 x Relays, Analog Output, Modbus Output, Audible & Visual Alarms - NH3, 0-100% LEL, Catalytic Bead

Bacharach 6302-2070 MGS-450 Gas Detector - IP66, 3 x Relays, Analog Output, Modbus Output, Audible & Visual Alarms - NH3, 0-100%...

$1,017.90

6302-2070 MGS-450 Gas Detector - IP66, 3 x Relays, Analog Output, Modbus Output, Audible & Visual Alarms - NH3, 0-100% LEL, Catalytic Bead by Bacharach

Bacharach's MGS-400 Gas Detectors makes compliance with mechanical equipment room and refrigeration safety codes simple and easy, saving time and money on equipment and installation. Using the MGS-400 App, users can intuitively use, commission and maintain their gas detection system without the need for specialty training or tools. Pre-calibrated sensor modules simplify maintenance, take minutes to exchange and do not require the use of calibration gas. The MGS-400 sensors can trigger additional audio-visual alarms and act as a standalone gas detection system, or integrate easily into a BMS / BAS or with Bacharach's optional MGS-408 Gas Detection Controller.

Features

  • Mobile App Interface
  • Pre-calibrated Sensors
  • Semi-automated Calibration
  • Remote Sensor Option
  • Temperature-Compensated Measurement
  • Low Temperature Performance
  • Digital Communications
  • Analog Outputs
  • Relay outputs
  • Audio & Visual Alarms
  • Multiple Cable Entries and Terminals

Benefits

  • Quick, easy and intuitive commissioning, configuration and maintenance requires no special training. No tools required to set alarm levels and behavior
  • Fast and easy sensor maintenance. Eliminates need for calibration gas.
  • Easy calibration process with mobile app. Generate calibration certificates for documentation.
  • Locate the sensor element in hard-to-reach areas and the base unit where convenient for electrical and communication wiring (MGS-460)
  • Mitigates false alarms and optimizes accuracy in refrigeration applications.
  • Suitable for use in cold rooms and freezers down to -40° F/C.
  • Integrate with local BMS/BAS via Modbus RTU
  • For current or voltage output to legacy systems (MGS-450/460)
  • 3 relays available for alarm and fault events to active horn/strobes and ventilation (MGS-450, MGS-460)
  • On-board alarm notification supports compliance with ASHRAE 15 / EN 378
  • Quick and easy installation of all wiring; daisy-chain power and digital communications.
PRODUCT CONFIGURATIONS
MGS-410
MGS-450
MGS-460
Enclosure Rating   IP66 IP41, IP66 IP66
Configurable Relays Settings n/a SPDT, Low (1), High (2), Fault (3)
Rating Rating 1 A @ 30 VDC
Digital Communications   Modbus RTU
Analog Output Single configurable n/a 4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V
Sensor   Integrated Integrated Remote
Size   5.1" x 5.1" x 2.7" (130 x 130 x 68 mm) IP41: 6.5" x 6.5" x 3.0" (165 x 165 x 77 mm)
IP66: 6.5" x 6.5" x 3.4" (165 x 165 x 87 mm)
Base Unit: 6.5" x 6.5" x 3.4" (165 x 165 x 87 mm)
Remote Unit: 4.5" x 5.4" x 2.7" (115 x 136 x 68 mm)
Weight (Approx)   9.2oz (260 g) 1lb, 1oz (480 g) 1lb, 11.7oz (758 g)
SPECIFICATIONS
 
MGS-410
MGS-450
MGS-460
Gases and Range HFC's/HFO 1,000 ppm
CO2 5,000 / 10,000 / 20,000 / 30,000 / 40,000 / 50,000 ppm
NH3 100 / 1,000 / 5,000 / 10,000 / 100% LEL
O2 30 Vol%
CO 500 ppm
Combustible - Semiconductor (R-290, R-600, R-50, R-600a, HC-12a, R-717) 5,000 ppm
Combustible - NDIR (R-600, R-50, R-290) 100% LEL
Combustible - Catalytic (R-600, R-50, R-290, R-717) 100% LEL
NO2 20 ppm
Status Indicator   Single Tri-color LED (green, red, orange)
Audio Alarm   Buzzer, 72db @ 10cm
Power   24V AC or DC (auto selecting), 4W (max)
Approvals   CE, UL / CSA / IEC EN 61010-1
Ambient Conditions Temperature  
Semiconductor -40 to 122°F / -40 to +50°C
Electrochemical NH3 100 / 1,000 ppm: -40 to 40°C
NH3 5,000 ppm: -20 to 40°C
CO 500 ppm: -40 to 50°C
NO2 20 ppm: -20 to 40°C
O2 30% Volume: -20 to 50°C
Infrared -40 to 122°F / -40 to +50°C
Catalytic Bead -40 to 122°F / -40 to +50°C
Humidity 5 to 90 % RH, non-condensing
Pressure 23.6 to 32.5 inch Hg / 800 to 1,100 mbar

Questions & Answers