- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach 5600-3012 GDX-350 Gas Sensor Transmitter/Monitor, [CO] 0-1,000 ppm, 3-wire - with Relays and Modbus
Item #:
5600-3012
Brand:
Bacharach
Share this product:
5600-3012 GDX-350 Gas Sensor Transmitter/Monitor, [CO] 0-1,000 ppm, 3-wire - with Relays and Modbus by Bacharach
Bacharach's new state-of-the-art GDX-350 transmitters, with Smart Sensor technology, provide accurate and continuous detection of toxic, combustible and asphyxiate gases. The full-featured design of the GDX-350 includes a large LCD display, a 4-20 mA interface, programmable alarms, optional relays and a Modbus interface. Exclusive pre-calibrated replacement sensor technology makes occasional maintenance practically effortless. Rugged construction, intrinsic safety capability (in two-wire mode with barrier) and an explosion-proof housing allow the GDX-350 to operate directly in hazardous-rated areas of many industrial environments, delivering reliable, superior-sensing performance to protect human life, equipment and property.
With its large LCD display, the GDX-350 shows gas concentrations, engineering units and bar graphs along with the most recent 30 minutes of trend data. Utilizing the on-board magnetic keypad, users can also navigate through the display to change alarm set points, instrument configurations, or enter into maintenance mode for non-intrusive sensor calibration. For security, menu options also enable the selection of an authorization code to lock critical parameters. Accompanying the LCD display are standard LED alarm indicators that show when low and high alarm conditions are met. An optional relay board is available to provide three 5-amp relays that can be used to drive audible/visual alarms, or activate exhaust fans.
Features & Benefits:
- Pre-calibrated Smart Sensor capability with 'plug-n-play' convenience minimizes maintenance and downtime
- Non-Dispersive Infrared (NDIR), Catalytic Bead and Electrochemical sensor options available
- Can be placed directly in hazardous environments where leaks occur for quick detection and rapid response
- Graphic LCD for real-time monitoring of concentrations
- 4-20 mA, optional Modbus RTUŽ and wireless interface
- Easily update alarm set points, configurations or maintenance modes using the LCD display
- 30-minute onboard data trend
Gas Type | Measuring Range | Display Increments | Sensor Type | Default Span Point | Default Low Alarm | Default High Alarm | Response Time (T90) |
Ammonia (NH3) | 0 - 500 ppm | 1 ppm | Electrochemical | 25 ppm | 25 ppm | 50 ppm | <75 s |
Carbon Dioxide (CO2) | 0 - 5% vol | 0.1% | Infrared (NDIR) | 2.5% | 1.5% | 2.5% | <50 s |
Carbon Monoxide (CO) | 0 -1,000 ppm | 1 ppm | Electrochemical | 100 ppm | 35 ppm | 70 ppm | <50 s |
Hydrogen (H2) | 0 - 1,000 ppm | 1 ppm | Electrochemical | 100 ppm | 50 ppm | 100 ppm | <180 s |
Hydrogen Sulfide (H2S) | 0 - 500 ppm | 1 ppm | Electrochemical | 25 ppm | 10 ppm | 20 ppm | <75 s |
Hydrocarbon (CH4) | 0 - 100% LEL | 1% | Infrared (NDIR) | 25% LEL | 10% LEL | 20% LEL | <60 s |
Methane (CH4) | 0 - 100% LEL | 1% | Catalytic Bead | 25% LEL | 10% LEL | 20% LEL | <45 s |
Nitrogen Dioxide (NO2) | 0 - 99.9 ppm | 0.1 ppm | Infrared (NDIR) | 5.0 ppm | 1.0 ppm | 2.0 ppm | <75 s |
Oxygen (O2) | 0 - 25% | 0.1% | Electrochemical | 20.9% | 19.5% | 18.5% | <30 s |
Phosphine (PH3) | 0 - 5 ppm | 0.01 ppm | Electrochemical | 1.00 ppm | 0.30 ppm | 0.60 ppm | <60 s |
Propane (C3H8) | 0 - 100% LEL | 1% | Infrared (NDIR) | 25% LEL | 10% LEL | 20% LEL | <60 s |
Sulfur Dioxide (SO2) | 0 - 99.9 ppm | 0.1 ppm | Electrochemical | 5.0 ppm | 2.0 ppm | 4.0 ppm | <45 s |
Dimensions | 8.0" x 5.5" x 4.61" (20.32 cm x 13.97 cm x 11.71 cm) | ||||||
Housing | Durable Aluminum Enclosure - Suitable for Class 1, Div. 1 & 2, Groups B, C, D | ||||||
Front Panel | 5 Indicator Lights: Alarm 1, Alarm 2, Fail, In Calibration, and RS-485 | ||||||
User Interface | 64 x 128 Pixel LCD Graphic Display for Gas Readings, 30 Minute Trend, Bar Graphing, Engineering Units and Backlight | ||||||
Operating Temperature Range | -40°F to 140°F (-40°C to 60°C) | ||||||
Ambient Humidity Range | 5% - 90% RH Non-Condensing | ||||||
Security Mode | Lock Out Critical Parameters | ||||||
4-20 mA Output Signal | 3-wire, 4-20 mA. Max Loop Resistance is 750 Ω (@24 VDC) | ||||||
Alarm Relays | 3 Configurable Form C (SPDT) Relays rated for 5 amp at 30 VDC or 240 ~ VAC RESISTIVE. | Relay 1 and Relay 2 Level Alarms are configurable for HIGH or LOW Trip, for Normally Energized (Failsafe) or Normally De-Energized and for Latching or Non-Latching. Relay 3 is always Normally Energized for Failsafe Operation so any loss of power to the GDX-350 will be indicated as a “FAULT” condition. | ||||||
Communications | RS-485, Modbus® | ||||||
Power | 10 - 30 VDC, 250 mA (@ 24 VDC) | ||||||
Power Safety Mode | Fully automatic system reset. All program parameters are retained. | ||||||
Approvals | CSA: Division 1 & 2, Class 1: Groups B, C, D (excludes NH3) |