1-866-4 JJSTECH(1-866-455-7832)

Bacharach 5201-2102 GDC-150 Gas Sensor Transmitter, NEMA 4 Housing, H2S Sensor, w/Display

Item #:
5201-2102
Brand:
Bacharach
Bacharach 5201-2102 GDC-150 Gas Sensor Transmitter, NEMA 4 Housing, H2S Sensor, w/Display
$1,242.15
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 5201-2102 GDC-150 Gas Sensor Transmitter, NEMA 4 Housing, H2S Sensor, w/Display

Bacharach 5201-2102 GDC-150 Gas Sensor Transmitter, NEMA 4 Housing, H2S Sensor, w/Display

$1,242.15

5201-2102 GDC-150 Gas Sensor Transmitter, NEMA 4 Housing, H2S Sensor, w/Display by Bacharach

The all new GDC-150 transmitter from Bacharach offers detection and protection for a wide range of hazards including toxic gases such as carbon monoxide (CO), oxygen depletion, combustible gases, refrigerant leaks and total volatile organic compounds (TVOCs). Analog interfaces allow the transmitter to be connected back to Bacharach's GDA Series of controllers (or any other gas detection controller), building management systems or control systems. The GDC-150 features 4-20 mA or 0-10 VDC linear output signals, an automatic thermal resetting fuse, RoHS compliant circuit boards and LED indicators for power and open loop.

The onboard alarm LED's indicate when alarm threshold values are exceeded. The unit can be ordered with an optional alpha numeric LED display that shows gas concentrations in real time while alarm relays alert personnel of potential dangers, avoiding incidents and potential hazards.

The GDC-150 is packaged in a rugged, polycarbonate housing for both indoor and outdoor applications. When leaks occur, the GDC-150 sensors respond quickly and accurately to protect people and property. Automated calibration and simple maintenance procedures performed in the field allow for continuous operation and assurance that areas are monitored and protected at all times.

Gases Detected Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), Nitrogen Dioxide (NO2), Ammonia (NH3), Nitric Oxide (NO), Sulfur Dioxide (SO2), Formaldehyde (HCHO), Combustible Gases (LEL), Refrigerants and Total Volatile Organic Compounds (TVOCs)
 
CO
H2S
O2
NO2
NH3
NO
SO2
Range:
Resolution:
0-200 ppm
1 ppm
0-50 ppm
0.5 ppm
0-25% Vol.
0.1% Vol.
0-10 ppm
0.1 ppm
0-500 ppm
1-2 ppm
0-100 ppm
1 ppm
0-20 ppm
1 ppm
 
HCHO
LEL (Catalytic)
LEL (Solid State)
Refrigerants
TVOC (PID)
TVOC (PID)
TVOC (Solid State)
Range:
Resolution:
0-10 ppm
0.1 ppm
0-100%
1%
0-50%
1%
0-2,000 ppm
1 ppm
0-50 ppm
0.1 ppm
0-300 ppm
1 ppm
0-500 ppm
1 ppm
Detection Principle Electrochemical, Solid State, Catalytic Bead, Photoionization Detector (PID)
Temperature -4° F to 104° F (-20° C to 40° C)
Relative Humidity 15-95% RH Non-Condensing
Housing Options Standard: Rugged PVC with hinged, secured, drip-proof door
NEMA 4X: Water and dust-tight, corrosion resistant polycarbonate with hinged, secured door
User Interface One tricolor LED: Green = power, Red = alarm, Flashing Red = fail
Amber color LED, internal relay coil status indicator (only supplied with relay option)
Alarm Relay Optional, one only S.P.D.T. dry contact relay rated 2 amp at 30V
Indicators 4-20 mA "open loop" indicator (red LED) for remote transmitter
Dimensions Standard: 4.43” L x 6.5” W x 2.54” D (113 mm x 165 mm x 65 mm)
NEMA 4X: 5.05” L x 5.05” W x 3.05” D (129 mm x 129 mm x 77 mm)
Weight Standard: 20 oz (0.57 kg)
NEMA 4X: 16 oz (0.45 kg)
Outputs Linear 4-20 mA or 0-10 VDC signal, jumper selectable
Wiring VDC 3 conductor shielded; VAC 4-conductor shielded
Fuse Automatic resetting thermal
Power 12-30 VAC or 16-30 VDC (non-ground reference supply only)
Approvals C-Tick Certified

Questions & Answers