- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector, NO2 0-10 ppm Toxic Sensor 3/4NPT CSA - 2106B1822
Item #:
2106B1822
Brand:
Honeywell Analytics
Share this product:
2106B1822 Sensepoint Hazardous Area Approved Gas Detector, NO2 0-10 ppm Toxic Sensor 3/4NPT CSA by Honeywell Analytics
The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics' controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/IECEx safety and performance standards.
The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.
The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of 'sticky' gases such as Chlorine and Ammonia.
Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.
Fit For Purpose
- Flammable, toxic and Oxygen versions available
- High performance, low cost
- Suitable for new and retro fit applications
Proven Sensor Technology
- Surecell™ electrochemical sensors
- Poison resistant catalytic bead
- Fast and reliable
- Typical 2 to 5 years operational life
ATEX/IECEx Certified
- Complies with the latest standards
- Hazardous area approval and performance
- IP65/67 for use in harsh environments
Easy to Use
- Factory set operation
- Simple to replace
- Minimal training required
Range of Accessories
- Weatherproof cap
- Flow adaptor
- Duct mounting kit
- Collecting cone
Gas & Range |
Flammable 0-100% LEL |
Flammable PPM (Typically 0-10% LEL) |
Hydrogen Sulphide (H2S) 20/50/100ppm |
Carbon Monoxide (CO) 100/200/500ppm |
Ammonia (NH3) 50/1000ppm |
Chlorine (Cl2) 5/15ppm |
Oxygen (O2) 25% V / V |
Hydrogen (H2) 1000/10000ppm |
Sulfur Dioxide (SO2) 15/50ppm |
Nitric Oxide (NO) 100ppm |
Nitrogen Dioxide (NO2) 10ppm |
Operating Temp | -40 to +80°C |
-30 to +65°C |
-25 to +50°C |
-20 to +50°C |
-20 to +40°C |
-20 to +50°C |
-15 to +40°C |
||||
Operating Humidity | Continuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing) |
||||||||||
Storage Conditions | 0 to 25°C; 30 to 70% RH |
0 to 25°C; 30 to 70% RH |
|||||||||
Operating Pressure | 90 to 110kPa |
||||||||||
Warm-up Time | < 10 minutes |
< 20 minutes |
< 3 minutes |
< 5 minutes |
< 3 minutes |
12 hours |
1 hour |
||||
Response Time | |||||||||||
T20 | < 6 secs |
< 5 secs |
- |
< 10 secs |
< 3 secs |
- |
- |
< 3 secs |
< 15 secs |
||
T50 | < 5 secs |
< 15 secs |
< 12 secs |
< 10 secs |
< 20 secs |
< 5 secs |
< 10 secs |
< 10 secs |
< 5 secs |
< 30 secs |
|
T90 | < 10 secs |
< 40 secs |
< 30 secs |
< 65 secs |
< 105 secs |
< 10 secs |
< 45 secs |
< 90 secs |
< 30 secs |
< 60 secs |
|
Supply | 200mA; 0.7W maximum |
18 to 30VDC; 0.9W maximum |
|||||||||
Signal Output | mV bridge |
Loop powered 4-20mA |
|||||||||
Linearity | < 5% fsd or ±10% of reading |
< 5% fsd |
|||||||||
Operating Life | 5 years (typical) |
2 years (typical) |
18 months (typical) |
1 year (typical) |
18 months (typical) |
||||||
Storage Life | Typically, over 5 years when in original sealed packagin |
6 months |
|||||||||
Stability (zero) | |||||||||||
with time | < ±3% fsd / yr |
< ±2% fsd / yr |
|||||||||
with temperature | < ±1% fsd |
< ±3% fsd |
< ±5% fsd |
< ±6% fsd |
< ±2% fsd |
< ±2% fsd |
< ±5% fsd |
||||
with humidity | < ±1% fsd |
< ±10% fsd |
< ±2% fsd |
< ±10% fsd |
< ±2% fsd |
< ±2% fsd |
< ±10% fsd |
||||
Stability (span) | |||||||||||
with time | < ±3% fsd / yr |
< ±2% fsd / yr |
< ±4% fsd / yr |
< ±20% fsd / yr |
< 10% fsd / yr |
< ±20% fsd / yr |
< ±2% fsd / yr |
||||
with temperature | < ±3% fsd |
< ±8% fsd |
< ±25% fsd |
< ±20% fsd |
< ±20% fsd |
< 40% fsd |
< ±10% fsd |
< ±60% fsd |
< ±15% fsd |
< ±25% fsd |
|
with humidity | < ±2% fsd |
< ±10% fsd |
< ±2% fsd |
< ±10% fsd |
< ±2% fsd |
< ±1% fsd |
< ±2% fsd |
< ±10% fsd |
|||
Weight | 190g |
185g |
205g |
185g |
|||||||
Construc. Materials | Polyphenylene Sulphide (PPS) |
||||||||||
I.P. (NEMA) Rating | IP65 (standard), IP67 (with weather protection fitted) |
||||||||||
Other Certifications | Russian: GOST |
||||||||||
Applicable Standards | This product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1 |