1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector, SO2 0-15 ppm Toxic Sensor 3/4NPT CSA - 2106B1820

Item #:
2106B1820
Brand:
Honeywell Analytics
Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector, SO2 0-15 ppm Toxic Sensor 3/4NPT CSA - 2106B1820
$1,533.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector, SO2 0-15 ppm Toxic Sensor 3/4NPT CSA - 2106B1820

Honeywell Analytics Sensepoint Hazardous Area Approved Gas Detector, SO2 0-15 ppm Toxic Sensor 3/4NPT CSA - 2106B1820

$1,533.00

2106B1820 Sensepoint Hazardous Area Approved Gas Detector, SO2 0-15 ppm Toxic Sensor 3/4NPT CSA by Honeywell Analytics

The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics' controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/IECEx safety and performance standards.

The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.

The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of 'sticky' gases such as Chlorine and Ammonia.

Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Fit For Purpose

  • Flammable, toxic and Oxygen versions available
  • High performance, low cost
  • Suitable for new and retro fit applications

Proven Sensor Technology

  • Surecell™ electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life

ATEX/IECEx Certified

  • Complies with the latest standards
  • Hazardous area approval and performance
  • IP65/67 for use in harsh environments

Easy to Use

  • Factory set operation
  • Simple to replace
  • Minimal training required

Range of Accessories

  • Weatherproof cap
  • Flow adaptor
  • Duct mounting kit
  • Collecting cone
Gas & Range
Flammable 0-100% LEL
Flammable PPM (Typically 0-10% LEL)
Hydrogen Sulphide (H2S) 20/50/100ppm
Carbon Monoxide (CO) 100/200/500ppm
Ammonia (NH3) 50/1000ppm
Chlorine (Cl2) 5/15ppm
Oxygen (O2) 25% V / V
Hydrogen (H2) 1000/10000ppm
Sulfur Dioxide (SO2) 15/50ppm
Nitric Oxide (NO) 100ppm
Nitrogen Dioxide (NO2) 10ppm
Operating Temp
-40 to +80°C
-30 to +65°C
-25 to +50°C
-20 to +50°C
-20 to +40°C
-20 to +50°C
-15 to +40°C
Operating Humidity
Continuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing)
Storage Conditions
0 to 25°C; 30 to 70% RH
0 to 25°C; 30 to 70% RH
Operating Pressure
90 to 110kPa
Warm-up Time
< 10 minutes
< 20 minutes
< 3 minutes
< 5 minutes
< 3 minutes
12 hours
1 hour
Response Time
T20
< 6 secs
< 5 secs
-
< 10 secs
< 3 secs
-
-
< 3 secs
< 15 secs
T50
< 5 secs
< 15 secs
< 12 secs
< 10 secs
< 20 secs
< 5 secs
< 10 secs
< 10 secs
< 5 secs
< 30 secs
T90
< 10 secs
< 40 secs
< 30 secs
< 65 secs
< 105 secs
< 10 secs
< 45 secs
< 90 secs
< 30 secs
< 60 secs
Supply
200mA; 0.7W maximum
18 to 30VDC; 0.9W maximum
Signal Output
mV bridge
Loop powered 4-20mA
Linearity
< 5% fsd or ±10% of reading
< 5% fsd
Operating Life
5 years (typical)
2 years (typical)
18 months (typical)
1 year (typical)
18 months (typical)
Storage Life
Typically, over 5 years when in original sealed packagin
6 months
Stability (zero)
with time
< ±3% fsd / yr
< ±2% fsd / yr
with temperature
< ±1% fsd
< ±3% fsd
< ±5% fsd
< ±6% fsd
< ±2% fsd
< ±2% fsd
< ±5% fsd
with humidity
< ±1% fsd
< ±10% fsd
< ±2% fsd
< ±10% fsd
< ±2% fsd
< ±2% fsd
< ±10% fsd
Stability (span)
with time
< ±3% fsd / yr
< ±2% fsd / yr
< ±4% fsd / yr
< ±20% fsd / yr
< 10% fsd / yr
< ±20% fsd / yr
< ±2% fsd / yr
with temperature
< ±3% fsd
< ±8% fsd
< ±25% fsd
< ±20% fsd
< ±20% fsd
< 40% fsd
< ±10% fsd
< ±60% fsd
< ±15% fsd
< ±25% fsd
with humidity
< ±2% fsd
< ±10% fsd
< ±2% fsd
< ±10% fsd
< ±2% fsd
< ±1% fsd
< ±2% fsd
< ±10% fsd
Weight
190g
185g
205g
185g
Construc. Materials
Polyphenylene Sulphide (PPS)
I.P. (NEMA) Rating
IP65 (standard), IP67 (with weather protection fitted)
Other Certifications
Russian: GOST
Applicable Standards
This product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1

Questions & Answers