1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics E3Point Gas Monitor with Remote Sensor, Nitrogen dioxide (NO2) - 1309A0057

Item #:
1309A0057
Brand:
Honeywell Analytics
Honeywell Analytics E3Point Gas Monitor with Remote Sensor, Nitrogen dioxide (NO2) - 1309A0057
$730.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics E3Point Gas Monitor with Remote Sensor, Nitrogen dioxide (NO2) - 1309A0057

Honeywell Analytics E3Point Gas Monitor with Remote Sensor, Nitrogen dioxide (NO2) - 1309A0057

$730.00

1309A0057 E3Point Gas Monitor with Remote Sensor, Nitrogen dioxide (NO2) by Honeywell Analytics

Toxic/combustible gas monitor that makes a commercial operation run more intelligently to protect people, property and the bottom line.

Product Overview:

E3Point is capable of detecting the widest range of toxic and combustible gases found in commercial building spaces and outbuildings, including CO, NO2, O2, H2, H2S, CH4 and C3H8. It can be used as a standalone unit with single or dual-gas detection (i.e. using a remote sensor) or deployed as a networkable device (interoperable with BACnet, Modbus or other Building Automation System): E3Point also functions with existing controller-based gas monitoring systems and wired-wireless gas monitoring system components.

E3Point uses Demand Control Ventilation—through relays, Building Automation System (BAS) or controller—to increase energy savings, extend fan life and align with green building best practices. In its network configuration, E3Point also optimizes HVAC, fire/smoke, surveillance and other building systems performance.

Intelligent product design reduces the unit's cost of ownership while increasing flexibility of application. Smart sensors are pre-calibrated, auto-configure upon set-up and operate continuously on patented Reflex© technology which continuously monitors sensor cell condition and alerts user to fault status. The plug-n-play sensor cartridge, user-friendly menu and wiring options simplify installation and maintenance, and reduce the cost of gas monitoring over the life of the unit.

Flexible Operation:

  • Comes in standalone, standalone with remote (dual gas mode) or network versions
  • Connects to analog or digital systems
  • Works with virtually any BAS including BACnet and Modbus
  • Connects to wired or wireless system (via 301CW wireless controller)
  • Wall or duct mount
  • Factory-calibrated cartridges

Cost Effective:

  • Saves energy through Demand Control Ventilation (DCV)
  • Simplifies installation/maintenance through plug-n-play sensor
  • Remote sensor option provides dual gas monitoring (standalone version only)
  • Optimizes BAS, fire, ventilation and other security systems

Versatile Communications:

  • Works through BAS to improve fault diagnostics and collect data on gas concentration levels, sensor condition, etc.
  • Couple with 301C to log data and daisy-chain up to 96 E3Point units

Advanced Sensing Technology:

  • Detects CO, NO2, O2, H2, H2S, CH4, C3H8
  • Advanced electrochemical (for toxic gases)and catalytic bead (for combustible gases) sensor performance
  • Uses patented Reflex® and smart cartridge technologies

Electrical Certifications:

  • US (ANSI/UL 61010-1)
  • Canada (CSA C22.2 No. 61010-1)

Features & Benefits:

  • Standalone, standalone with remote (dual gas mode) or network versions available
  • Saves energy through Demand Control Ventilation

Quick Specs:

  • Complete toxic and combustible gas detection system with onboard sounder
  • Available in single point or dual gas options
  • Analog 4-20 mA or Digital outputs (Bacnet, Modbus, and Lonworks)
General Specification
Use Wall or duct-mounted gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), methane (CH4), hydrogen (H2), hydrogen sulphide (H2S), and propane (C3H8), installed as a standalone device with single-gas or dual-gas monitoring.
Size 20.56 x 14.90 x 6.72cm (8.09 x 5.87 x 2.65") (H x W x D); Remote Sensor: 3.5 x 4.5 x 6.5 cm (1.36 x 1.75 x 2.56")
Power Requirement 24 Vac nominal (17-27Vac), 50/60 Hz, 0.35 A; 24Vdc nominal (20-38Vdc); with remote sensor: 7 W max.
Optional Main AC Input 120Vac nominal, ± 10% (with on-board transformer)
Relay Output 2 DPDT relays, 5A @ 250Vac; 5A @ 30Vdc
Communications 4-20mA
Operating Environment Commercial, Indoor, Extreme Temperature Environments
Operating Temperature H2S, NO2, O2, CH4, H2, C3H8: -40 to 50ºC (-40 to 122ºF)
CO: -20 to 50ºC (-4 to 122ºF)
Sensor Type Electrochemical cell (CO, NO2, H2S, O2); catalytic (CH4, H2, C3H8,)
Response Time T90 < 50 seconds
With ECLAB T90 < 240 seconds
Display 8 character, 2 line backlit LCD
Visual Indicators Green LED: Power
Amber LED 1: Alarm/Fault
Amber LED 2: Alarm/Fault
Audible Alarm >85 dBA at 3 m (10 ft)
Accuracy ± 3% of full scale @ 25ºC
Detection Ranges and Alarm Levels
Gas
Resolution
Range
Alarm A
Alarm B
Alarm C
CO (Carbon monoxide)
1 ppm
0-250 ppm
25 ppm
100 ppm
225 ppm
H2S (Hydrogen sulfide)
0.1 ppm
0-50 ppm
10 ppm
15 ppm
20 ppm
NO2 (Nitrogen dioxide)
0.1 ppm
0-10 ppm
0.7 ppm
2 ppm
9 ppm
O2 (Oxygen)
0.1% vol.
0-25% vol.
19.5% vol.
22% vol.
22.5% vol.
H2 (Hydrogen)
0.5% LEL
0-100% LEL
25% LEL
50% LEL
90% LEL
CH4 (Methane)
0.5% LEL
0-100% LEL
25% LEL
50% LEL
90% LEL
C3H8 (Propane)
0.5% LEL
0-100% LEL
25% LEL
50% LEL
90% LEL
Enclosure Polycarbonate
Certification CSA C22.2 No. 61010-1, UL 61010-1; FCC part 15; ICES-003 issue 4; ISO 9001-2008