- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
TPI 440 Single Input 1 MHz oscilloscope with True RMS DMM
Item #:
TPI-440
Brand:
Test Products International
Share this product:
440 Single Input 1 MHz oscilloscope with True RMS DMM by Test Products International
The TPI 440 is a hand-held oscilloscope plus autoranging DMM. The instruments large, backlit LCD display shows a reading and waveform simultaneously. In addition to the standard functions of ACV, DCV, ACA, DCA, Ω, Diode Test and Continuity Buzzer; the 440 measures Frequency (Hz),Capacitance, Logic and Component test functions. The 440 also has RS232 output and software for interfacing with a PC is offered as an optional accessory.
Features:
- Auto Ranging 4,000 Count True RMS DMM: TPI’s 440 has 9 measurement functions and 0.3% basic DC accuracy.
- 1 MHz Oscilloscope: View industrial power signals such as motor controls, UPS, switching power supplies, and PLC controls with detail and clarity.
- Trend Mode: Graph readings over a predetermined time period to check for surges or dropouts.
- Component Test: Check voltage-current signatures on resistors, capacitors, and semiconductors.
- Logic Test: Indicates transitions up to 2 MHz.
- Frequency Counter: Measure low frequency signals from 1Hz to 2 MHz and display duty cycle, pulse width and period.
- T-Base Button:Use feature to manually adjust sweep speed (time/division) to shrink or enlarge the viewable waveform for analysis.
- Continuous Autoset:Feature automatically determines the correct vertical and horizontal settings for optimum waveform viewing. Autoset provides hands free operation while moving between test points.
- PC/Printer Compatibility to RS-232C Port:Optional accessory A402 allows user to download data or waveforms to a PC for archiving, processing, and report generation. Perfect for extended monitoring. Eight waveform storage locations enables remote data acquisition for later viewing.
Applications:
- Industrial motor control: View start-up in rush currents, waveform symmetry, SCR trigger pulses, variable frequency drive signals, pulse width modulation, noise, miscellaneous AC/DC speed control signals, and synchronous motor and generator field excitation controls.
- Power quality: Define AC voltage wave shapes, current waveforms, machine start-up and power quality interference, and noise on industrial feeds and/or general noise.
- Battery testing: Measure voltage drops in Gel-Cell type batteries when connected in circuit. Measure stationary battery charger float and equalize voltages and individual cell voltages in DC backup power systems.
- Programmable logic controls: Read PLC input and output signals, control signals, signal conditioning circuits, communication lines and power supplies.
- NC/CNC machines: Check power quality, sensor outputs, control circuits, safety circuits, calibration and adjustments of components, relays and switches. Troubleshoot axis drives.
- Uninterruptable power supplies: Sense and monitor circuits, switching circuits, output waveforms and current waveforms.
- Audio: Locate noise spikes and voltage/current drops on all home/auto amplifiers, mixers, preamps, and paging system amplifiers.
- Video: Analyze horizontal and vertical scan rates, z-axis blanking, sync pulses and luminance.
- Industrial lighting controls:Troubleshoot SCR and Triac dimming controls and photo sensors. Measure lamp ballast voltages
- Factory automation: Robot control signals, machine vision, machine control and sensing circuits, calibration of positioning systems, analog controllers, and servo controls.
- Line conditioners: Detect noise and monitor waveform distortion
- Voltage regulators: Define noise and stability
- Inverters: Define waveform quality.
- Gaming Industry: Troubleshoot for component and capacitor degrading which causes noise to appear as periodic waveforms or rapid fluctuations. Most meters cannot catch these anomalies due to a slow sampling frequency. The 440 samples at 20 million times per second. This offers a visual graph of the voltage making it fast and simple for you to detect the noise.
DCV | |
Range | 400mV 4V 40V 400V 1000V |
Resolution | 0.1mV 0.001V 0.01V 0.1V 1V |
Accuracy | ± 0.3% of reading, ± 2 digits |
Impedance | more then 100MΩ 10MΩ |
ACV (20 Hz to 50 Hz) | |
Range | 300mV 3V 30V 300V 750V |
Resolution | 0.1mV 0.001V 0.01V 0.1V 1V |
Accuracy | ± 1.5% of reading, ± 10 digits |
Impedance | 1.11MΩ |
ACV (50 Hz to 1kHz, 1kHz to 10KHz) | |
Range | 300mV 3V 30V 300V 750V |
Resolution | 0.1mV 0.001V 0.01V 0.1V 1V |
10-30kHz | ± 2.5% of reading, ± 30 digits |
N/A | |
30-100kHz | ± 4% of reading, ± 200 digits |
N/A | |
100-200kHz | ± 10% of reading, ± 300 digits |
N/A | |
Impedance | 1.11MΩ |
DCA | |
Range | 400μA 4000μA 40mA 400mA 4A 10A |
Resolution | 0.1μA 1μA 0.01mA 0.1mA 0.001A 0.01A |
Accuracy | ± 0.5% of reading, ± 5 digits |
± 0.75% of reading, ± 5 digits | |
Overload Protection | Fuse* (fast blow) F600V, 0.5A, 31CM F600V, 10A, 31CM |
ACA | |
Range | 300μA 3000μA 30mA 300mA 3A 10A |
Resolution | 0.1μA 1μA 0.01mA 0.1mA 0.001A 0.01A |
20-50Hz | ± 1.0% of reading, ± 10 digits |
50Hz-3kHz | ± 0.75% of reading, ± 10 digits |
3-10kHz | ± 2.0% of reading, ± 20 digits |
N/A | |
10-30kHz | ± 2.0% of reading, ± 40 digits |
N/A | |
OHM (Resistance) | |
Range | 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 30MΩ |
Resolution | 0.1Ω 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ 0.01MΩ |
Accuracy | ± 0.3% of reading, ± 10 digits |
± 0.3% of reading, ± 2 digits | |
± 1.0% of reading, ± 10 digits | |
± 1.5% of reading, ± 20 digits | |
Overload Protection | 600V DC or AC Peak |
Continuity Buzzer | |
Test Voltage | 3V |
Threshold | 100 digits |
Overload Protection | 600 V DC or Peak AC |
Diode Test | |
Test Voltage | 3V |
Max Test Current | Approx. 2.5mA |
Over Load Protection | 600V DC or AC Peak |
Capacitance | |
Range | 400.0nF 4.0μF 40.0μF 400.0μF |
Resolution | 100pF |
Accuracy | ± 3% of reading, ± 5 digits |
Over Load Protection | 600V DC or AC Peak |
Frequency | |
Range | 100.00Hz 1.0000Hz 10.000kHz 100.00kHz 1.0000MHz 2.0000MHz |
Resolution | 0.01Hz 0.1Hz 1Hz 10Hz 100Hz 100Hz |
Accuracy | ± 0.05% of reading, ± 1 digits |
Overload Protection | 600V DC or Peak AC |
General Specifications | |
Max. Volt. between any Input and Ground | 1000V |
Basic DC Accruracy | 0.3% |
Frequency Counter Range | 2MHz |
Meter AC Bandwidth | 200kHz |
Waveform Display Bandwidth | 1 MHz |
Fuse Protection | mA: 0.5Amp/600VAC A: 10Amp/600VAC |
Display Type | Super-twist LCD, 160 x 240 pixels |
Operating Temperature | 0° to 50° C (32° to 122° F) |
Storage Temperature | -20° to 60° C (-4° to 140° F) |
Realtive Humidity 0% to 80% | (0° - 35° C/32° - 95° F) 0% to 70% (35° - 55° /95° - 131°F ) |
Temperature Coefficient | 0.1 x (Specified Accuracy) per °C for temperature <18°C to >28° C |
Power Supply | Nicad Battery 7.2V, AA cell x 8 |
Battery Life Time | 5 Hours |
Battery Charge Time | 3 Hours |
Safety Designed | Pollution Degree 2, Overvoltage Cat. II 1000V, Cat. III 600V per IEC 1010, UL3111 and C22.2 No. 1010-1 |
Size (H x L x W) | 52 x 220 x 100nm |
Weight | 1 lb. 6 oz |
Features and Benefits | |
Approvals | Meets CE and IEC 1010 requirements |
True RMS | Needed to accurately measures non-sinusodial AC voltage and current waveforms foun on many controls and circuits. |
Auto Set | 440 automatically sets up the scope depending on the magnitude of the signal being measured |
Real Time Update | Tracks events as they happens |
Glith Capture | Finds spikes in signals |
Relative Mode | LCD displays the difference between the measured value and a stored value |
Trend Mode | Graphs signals to find problems with circuits |
Record Mode | Records Min/Max and Average values. Time reference when value was obtained. |
Compare Mode | Compare stored value with measured value for matching componenets. |
Relative % Mode | Displays measured value as percentage of percentage of stored value for checking component tolerances. |
RS232 Output | Transfers data directly to a PC while measuring |
Back Light | Allows Viewing in any light condition. |
Autorange | Automatically selects best range for measurement. |
Low Battery Indication | Battery should be charged when battery symbol displays on LCD. |