- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
TPI 192 True RMS 50,000 count DMM with Inductance
Item #:
TPI-192
Brand:
Test Products International
Share this product:
192 True RMS 50,000 count DMM with Inductance by Test Products International
The Triple Display 192 is an innovative new concept in DMM design. The unique display enables you to view more than one event at a time. This eliminates the hassle of switching back and forth to review minimum, maximum or preset comparative values. The meter is also easy to use and built to last.
The DMM 192 is a hand-held autoranging DMM. The backlit LCD can display three readings at one time. In addition to basic function of AC/DC V, AC/DC A, Ohm, Diode test, continuity, Capacitance, Frequency, there is the adaptor function. The meter also has RS232 output and software for recording information into a PC.
Features:
- REC: Records Min/Max and Average readings during specified measurement intervals.
- COMP: Compare actual reading to preset HI and LOW value for Pass/Fail testing of component
- Hold: Tow hold system automatically holds the previous stable reading when a new one is obtained.
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- Inductance, Frequency and Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- cULus 61010-1
- CATIII-1000VC, CATIII-1000V, CAT IV-600V, CAT III 1000V
- True RMS DMM
- Time Stamp Logging
- Optional PC Output with A192
- Pulse Width
- Duty cycle (% pulse width modulation) for measuring modulating gas valves
Applications:
- Thermocouples in furnaces or gas applications
- Heat anticipator current in thermostats
- Line voltage
- Control circuit voltage
- Flame safeguard control current
- Heating element resistance (continuity)
- Compressor winding resistance
- Contactor and relay coil resistance
- Continuity of wiring
- Motor start and run capacitance
- Frequency on controls and line voltages
- Record min/max voltage of controls and line voltages
- Temperature with optional temperature adapter (A310)
- Bar graph to indicate rapid fluctuations in measurements
- Voltage of direct drive DC motors
- Measure power supply voltage
- Match components
- Compare readings in circuits and components
- Frequency of line and control voltage
DC Volts | Maximum Input: 1000V Maximum Resolution: 0.0001mV Accuracy: ± 0.05% |
AC Volts | Maximum Input: 1000V Maximum Resolution: 100μV Accuracy: ± 0.4% |
DC Amps | Maximum Input: 10A Maximum Resolution: 0.01μA Accuracy: ±0.15% |
AC Amps | Maximum Input: 10A Maximum Resolution: 0.01μA Accuracy: ± 0.75% |
Resistance (Ohms) | Maximum Input: 50MΩ Maximum Resolution: 0.1mΩ Accuracy: ± 0.05% |
Frequency | Maximum Input: 5MHz Maximum Resolution: 0.001Hz Accuracy: ± 0.05% |
Capacitance | Maximum Input: 20mF Maximum Resolution: 0.01nF Accuracy: ± 2% |
Inductance | Maximum Input: 300mH Maximum Resolution: 0.01mH Accuracy: ± 5% |
Temperature (K-Type Thermocouple) | Maximum Input: -54°F to 2462°F (-50°C to 1350°C) Maximum Resolution: 0.1°F / °C Accuracy: ± 2% |
Continuity | Audible at less than 10 Ω |
Diode | 3V at 1mA maximum output |
Duty Cycle | Maximum Input: 99.9% Maximum Resolution: 0.1% |
True RMS Responding | Yes |
Conductance | Yes |
Pulse Width | Yes |
Data Hold | Yes (Two hold system) |
Min/Max Record | Yes |
Time Stamp Logging | Yes |
Relative Mode | Yes |
Compare Mode | Yes |
RS-232 Output | Yes, Optically Isolated |
Process Loop Output | No |
Sleep Mode / Auto Off | Yes |
Protective Boot | Yes (standard) |
Display Type | 50,000 count backlit LCD with dual sub displays and analog bargraph |
Range Selection | Auto / Manual |
Operating Temperature | 32°F to 113°F (0°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Humidity | 80% non-condensing |
Size | 8.3" x 3.7" x 1.9" (210mm x 95mm x 47mm) without boot 8.7" x 4.3" x 2.6 (220mm x 110mm x 65mm) with boot |
Weight | 1.3lbs (570g) without boot 1.9lbs (850g) with boot |
Battery Type | 9V Alkaline (NEDA 1604) |
Battery Life | 50hrs Typical |
OverInput Category | CAT III 600V |
Agency Approval | cULus 61010-1, IEC 61010-1 |
Warranty | Limited Lifetime |