- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
TPI 133 Manual Ranging DMM, with Boot, Test Leads, Battery and Manual
Item #:
TPI-133
Brand:
Test Products International
Share this product:
133 Manual Ranging DMM, with Boot, Test Leads, Battery and Manual by Test Products International
The 133 is a hand-held autoranging DMM. It features extra large numerals on the LCD, and Data Hold for all functions and ranges. The 133 is an affordable choice offering measurements in all of the basic electrical functions.
Features:
- Safety: Meets CE and IEC 1010 requirements. UL Listed to U.S. and Canadian Safety Standards.
- Large LCD:Easy to read at all angles and the majority of lighting levels. 4000 Count.
- Rubber Boot: Added protection when the instrument is dropped. (135NB does not include boot.)
- Multi-function: Measure all electrical characteristics with one meter.
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 20MΩ; max resolution 0.1Ω
- 0 to 10 amps AC/DC; 0.1uA resolution
- Data Hold
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
Applications:
- Thermocouples in furnaces and gas appliances
- Heat anticipator current in thermostats
- Line and control voltages
- Flame safety control current
- Heating element resistance
- Continuity of wiring
- Line current up to 10 amps
- Power supply current
The 133 comes complete with the following accessories:
- 133 Instrument
- Rubber Boot (133NB does not include boot)
- Test Lead Set
- Battery
- Instruction Manual
DC Volts | Maximum Input: 1000V Maximum Resolution: 0.1mV Accuracy: ± 0.5% |
AC Volts | Maximum Input: 750V Maximum Resolution: 0.1mV Accuracy: ± 0.8% |
DC Amps | Maximum Input: 10A Maximum Resolution: 0.1μA Accuracy: ± 5% |
AC Amps | Maximum Input: 10A Maximum Resolution: 0.1μA Accuracy: ± 0.75% |
Resistance (Ohms) | Maximum Input: 20MΩ Maximum Resolution: 0.1mΩ Accuracy: ± 0.75% |
Frequency | N/A |
Capacitance | N/A |
Inductance | N/A |
Temperature (K-Type Thermocouple) | N/A |
Continuity | Audible at less than 100 Ω |
Diode | 2.5V at 1mA maximum output |
Duty Cycle | N/A |
True RMS Responding | No |
Conductance | No |
Pulse Width | No |
Data Hold | Yes |
Min/Max Record | No |
Time Stamp Logging | No |
Relative Mode | No |
Compare Mode | No |
RS-232 Output | No |
Process Loop Output | No |
Sleep Mode / Auto Off | No |
Protective Boot | Yes (standard) |
Display Type | 4000 count LCD |
Range Selection | Auto / Manual |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Storage Temperature | 14°F to 122°F (-10°C to 50°C) |
Humidity | 80% non-condensing |
Size | 7.4" x 3.4" x 1.2" (187mm x 86mm x 33mm) with boot |
Weight | 12oz (340g) with boot |
Battery Type | 9V Alkaline (NEDA 1604) |
Battery Life | 500hrs Typical |
OverInput Category | CAT III 600V |
Agency Approval | cULus 61010-1, IEC 61010-1 |