- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
GfG Dynagard Stand-alone System, Nitrogen Dioxide (NO2) - 3706-050
Item #:
3706-050
Brand:
GfG
Share this product:
3706-050 Dynagard Stand-alone System, Nitrogen Dioxide (NO2) by GfG
Single-point Area Monitors
Dynagard AutoCal® monitors are single point detection instruments that accurately measure toxic gases and oxygen levels. Alarm lights on the front panel illuminate and an internal horn sounds when gas concentrations are exceeded.
Simple and effective
The units accurately display values on a large backlit LED and can transmit a linear 4-20 mA output. AutoCal® calibration and maintenance is done effortlessly through front panel push-buttons. Smart sensors enable the user to change measuring ranges or gas types in the field without a need for additional programming. The Dynagard is equipped with onboard relays for two adjustable alarm points. It also has one sensor fault for local connection and activation or deactivation of external devices like strobes, fans, auto dialers etc.
Features
- AutoCal® automatic calibration
- Smart sensor technology
- Digital display / control connection
- Internal push-button alarm settings
Detection principal | Electrochemical |
Detection method | Diffusion |
Response time | T90 <5 sec. (depending on gas) |
Expected sensor life | 2 years (depending on gas) |
Display | 4 digit LCD Power, alarm and fault LED's |
Power supply | 115 VAC / 24 VDC |
Output signal | Linear 4-20 mA |
Relays | 2 alarm points, 1 fault – voltage free Voltage: 250 VAC 50/60 Hz or 250 VDC maximum Current: 4 A AC/DC maximum |
Horn | 95 dB at one foot |
Temperature range | +5 to +115˚F / -15 to +46˚C |
Humidity range | 15 to 96% rh |
Pressure range | 920 to 1,080 hPa |
Housing | UL 94 HB polystyrene enclosure with clear poly carbonate lid |
Weight | 2 pounds (907 g) |
Dimensions | 7.9x7.5x4.8 inches (200x190x120 cm (HxWxD) |
Housing approvals | IP 65 |
Accessories | Remote display / control |
Gases | Detection ranges |
Ammonia (NH3) | 0-200 or 1,000 ppm |
Carbon Monoxide (CO) | 0-500 or 2,000 ppm |
Chlorine (Cl2) | 0-50 or 250 ppm |
Chlorine Dioxide (ClO2) | 0-1.0 ppm |
Ethylene Oxide (C2H4O) | 0-20 ppm |
Hydrogen (H2) | 0-2,000 ppm or 0-4% volume |
Hydrogen Chloride (HCL) | 0-200 ppm |
Hydrogen Cyanide (HCN) | 0-200 ppm |
Hydrogen Sulfide (H2S) | 0-200 or 1,000 ppm |
Nitrogen Dioxide (NO2) | 0-50 or 200 ppm |
Oxygen (O2) | 0-25% volume |
Sulfur Dioxide (SO2) | 0-50 or 500 ppm |